Rated power 72W 100W 120W Open Frame Series
Electrical Parameters/Specifications:
Model No | MA120-12V6A | MA120-12V8A | MA120-24V4A | MA100-24V5A | |
Output | DC voltage | 12V | 12V | 24V | 24V |
Rated current | 6A | 8A | 4A | 5A | |
Current range | 0-8A | 0-10A | 0-6A | 0-7A | |
rated power | 72W | 100W | 100W | 120W | |
Ripple and Noise (Maximum) | 100mVp-p | 120mVp-p | 150mVp-p | 150mVp-p | |
Voltage accuracy | ±3% | ±3% | ±3% | ±3% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±1% | ±1% | ±1% | ±1% | |
Efficiency (TYP) | 85%(220V MAX) | 85%(220V MAX) | 88%(220V MAX) | 88%(220V MAX) | |
Voltage adjustment range | not adjustable | ||||
Start-up, rise time | 1500ms,30ms/220VAC 2500ms,30ms/110VAC (full load) | ||||
Input | voltage range | VAC90-264V VDC127~370V (Please refer to "Derating Curve") | |||
Frequency Range | 50/60Hz | ||||
AC current (TYP) | 1.1A/220VAC,1.8A/110V | ||||
Inrush current (TYP) | COLD START 35A | ||||
leakage current | <2mA/240VAC | ||||
Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
over current | 110%~200% of rated output current | ||||
over power | 110%~200% of rated output power | ||||
Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to "Derating Curve") | |||
Working humidity | 20~90%RH, no condensation | ||||
Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT, general standard design of home appliances, (customer certification test is required) | |||
Pressure resistance | I/P-O/P:1.5KVAC | ||||
Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
Electromagnetic Compatibility Emissions | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
Electromagnetic Compatibility Immunity | Refer to the general standard design of industrial safety regulations, (requires customer safety testing of the whole machine) | ||||
Size (L*W*H) | 105*57*25mm(L*W*H)(25MM is the height of board components) | ||||
weight | about 0.7Kg/PCS |
Remarks:
Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.
The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.
Derating curve graph
Static Characteristic Curve
Mechanical dimension drawing: unit MM
*Power Circuit Diagram:
Write your message here and send it to us