High Quality Single Type C port GaN PD30W Quick charger
PRODUCT Name | PD30W GaN Charger |
MODEL | JHX-AC2053 |
SPECIFICATION | AC 100-240V 50-60Hz 0.8A
DC PD 5V-3A/ 9V-3A/ 12V-2.5A/15V-2A/20V-1.5A (PPS)3.3V-11V 3A |
1、SCOPE:
Thedocumet detail the electrical ,mechamicaland environmental specifications of a smps the power supply provide 30w contimuous output power
The power supply shall meet the ROHS requirement
SMPS Adaptor(wall mount)
2、INPUT CHARACTERISTICS:
2. 1 Input Voltage Current/Frequency
The range of input voltage is from 90Vac to264Vac single phase
0.8A Max full load
Min | Nomimal | Max | |
Input | 90Vac | 100Vac-240Vac | 264Vac |
Input frequencu | 47HZ | 50/60HZ | 63HZ |
2.2 Inrush current
30A max @264Vac input
2.3 Efficiency
92% min average efficiency
3、OUTPUT CHARACTERISTICS:
3.1 Static output characteristics
3.2 Line load regulation load TYPE-C Interface
Ratedvoltage (V) | Load current(A) | Load voltage range(V) | |
5V | 3 0A | 4 75V | |
9V | 3.0A | 8.55V--9.45V | |
12V | 2.5A | 11.4V--12.6V | |
15V | 2.0A | 14.25V--15.75V | |
20V | 1.5A | 19.00V--21.00V |
3.3 turn –on delay time
3S max @100Vac to 240Vac input full load
3.4 hold-up time
10ms min @full load
3.5 Rise time:
20ms max @full load
3.6 fall time
60ms max full load
4、PROTECTION REQUIREMENTS
4.1 over current protection 130% max
The output shall hiccup when the over currents applied to the output ralland shall be self-recovery when the fault condition is removed
4.2 short circuit protection
the input power shall decrease when the output rail short .the power supply shall nodemage and shall be self-recovery when the fault condition is removed
4.3 Over voltage protection
4.4 Over temperature protection
4.5 Over charging protection
4.6 Over current protection
The output is turned off when the surface temperature of the integrated chip reaches 150°C.
5、ENVIRONMENTAL REQUIREMET:
5.1 operating temperature and relative humidity
0℃to +40℃ 5%RHto 95%RH
5.2 storage temperature and relative humidity
-20℃to +65℃ 0%rh non condensing
5.3 vibration
10to 300hz sweep at a constant acceleration of 1.0G (breadth 3.5mm)for 1 hours for each of the perpendicular axes x y z
5.4 Drop in
Height :1m the product be fell off on the hardwood with the thickness of 20mm,and hardwood shall be put on the base of the cement or on the ground without flexibility apply two times on all surface
6、Reliability requirements
6.1 Burn-in
The power supply shall be burn-in for 2 hours under normal input and 100% rated load at 35℃-40℃
6.2 MTBF qualification
The MTBF shall be at least 50000 hours at 25℃ full load and input condition
7、EMC standards EMC
7.1 EMC standards j55022
8、SAFETY STANDARDS
8.1 Dielectric strength(Hi-pot)
Primary to secondary:3000VAC
8.2 leakage current
5mA max at 3000VAC
8.3 insulation resistance
50M min at primary to secondary add 3000Vac test voltage
8.4 safety standards
Type / | Country | Standard |
PSE | Japan | J62368-1 |
9 Out Looking
9. 1 outline drawing 41 (L) *28 (W) *40.7 (H) mm
9.2 marking drawing