High-Quality 100W 200W Open Frame Switching Power Supply
Electrical Parameters/Specifications:
Model No | TASC120-12V8A | TASC120-12V10 | TASC120-24V4A | TASC120-24V5A | |
Output | DC voltage | 12V | 12V | 24V | 24V |
Rated current (natural cooling) | 8A | 10A | 4A | 5A | |
Current range | 0-8A | 0-10A | 0-4A | 0-5A | |
Rated power (free cooling) | 100W | 120W | 100W | 120W | |
Ripple and Noise (Maximum) | 100mVp-p | 100mVp-p | 120mVp-p | 120mVp-p | |
Voltage accuracy | ±2% | ±2% | ±2% | ±2% | |
Linear adjustment rate | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Load Regulation | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
Efficiency (TYP) | 88%(220V MAX) | 88%(220V MAX) | 87%(220V MAX) | 87%(220V MAX) | |
Voltage adjustment range | 10.5V~14.0V | 10.5V~14.0V | 22.5V~26.0V | 22.5V~26.0V | |
Start-up, rise time | 1500ms,30ms/220VAC 2500ms,30ms/110VAC(full load) | ||||
Input | voltage range | VAC90-264V VDC127~370V (Please refer to "Derating Curve") | |||
Frequency Range | 47~63Hz | ||||
AC current (TYP) | 1.1A/220VAC,2.2A/110V | ||||
Inrush current (TYP) | COLD START 45A | ||||
leakage current | <2mA/240VAC | ||||
Current Protection |
short circuit | Protection mode: hiccup mode, automatic recovery after abnormal condition is removed | |||
over current | 110%~200% of rated output current | ||||
over power | 110%~200% of rated output power | ||||
Environmental | Operating temperature | ﹣20~﹢60℃ (Please refer to "Derating Curve") | |||
Working humidity | 20~90%RH, no condensation | ||||
Storage temperature and humidity | ﹣40~﹢85℃,10~95%RH | ||||
Vibration resistant | 10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes | ||||
Safety and Electromagnetic Compatibility | safety regulations | Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass) | |||
Pressure resistance | I/P-O/P:3KVAC | ||||
Insulation resistance | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH | ||||
Electromagnetic Compatibility Emissions | Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass) | ||||
Electromagnetic Compatibility Immunity | Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass) | ||||
Mechanical | Size (L*W*H) | 101.6*50.8*36mm(L*W*H) | |||
weight | About0.7Kg/PCS |
Remarks:
Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.
The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.
Derating Curve
Static Characteristic Curve
*Mechanical Dimension Drawing: unit MM
*Power Circuit Diagram:
Write your message here and send it to us