Specifications for this item

* Ultra small shape design, easy to install

* Full load operation, low temperature rise

* Meet safety requirements, and isolation withstand voltage is greater than 3000VAC

*Compliant with EMC design, can be certified, low ripple processing.

*Optional synchronous rectification technology, higher efficiency and lower temperature rise.

* Output short circuit, over current, over power protection functions are perfect.


Product Detail

Product Tags

Electrical Parameters/Specifications:

Model No TASC120-12V8A TASC120-12V10 TASC120-24V4A TASC120-24V5A
Output       DC voltage                              12V 12V 24V 24V
Rated current (natural cooling)                                8A 10A 4A 5A
Current range                      0-8A 0-10A 0-4A 0-5A
Rated power (free cooling)                           100W 120W 100W 120W
Ripple and Noise (Maximum) 100mVp-p 100mVp-p 120mVp-p 120mVp-p
Voltage accuracy ±2% ±2% ±2% ±2%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±0.5% ±0.5% ±0.5% ±0.5%
Efficiency (TYP) 88%(220V MAX) 88%(220V MAX) 87%(220V MAX) 87%(220V MAX)
Voltage adjustment range 10.5V~14.0V 10.5V~14.0V 22.5V~26.0V 22.5V~26.0V
Start-up, rise time                 1500ms,30ms/220VAC  2500ms,30ms/110VAC(full load)
Input         voltage range                        VAC90-264V  VDC127~370V (Please refer to "Derating Curve")
Frequency Range                     47~63Hz
AC current (TYP) 1.1A/220VAC,2.2A/110V
Inrush current (TYP) COLD START 45A
leakage current                             <2mA/240VAC
Current
Protection   
short circuit Protection mode: hiccup mode, automatic recovery after abnormal condition is removed
over current 110%~200% of rated output current
over power 110%~200% of rated output power
Environmental Operating temperature ﹣20~﹢60℃ (Please refer to "Derating Curve")
Working humidity                   20~90%RH, no condensation
Storage temperature and humidity                     ﹣40~﹢85℃,10~95%RH
Vibration resistant                      10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes
Safety and Electromagnetic Compatibility       safety regulations Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass)
Pressure resistance I/P-O/P:3KVAC
Insulation resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH
Electromagnetic Compatibility Emissions Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass)
Electromagnetic Compatibility Immunity Refer to CE, CCC, IT, general standard design for home appliances (requires the whole product test to determine whether the parameters pass)
Mechanical Size (L*W*H) 101.6*50.8*36mm(L*W*H)
weight About0.7Kg/PCS

Remarks:

Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.

Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test.

Load regulation measurement method: from 0% to 100% rated load.

The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.

Derating Curve

Static Characteristic Curve

1665719851067

*Mechanical Dimension Drawing: unit MM

*Power Circuit Diagram: