Specifications for this item

* Ultra small shape design, easy to install

* Full load operation, low temperature rise

* Meet safety requirements, and isolation withstand voltage is greater than 1500VAC

* Refer to EMC design, can be certified, low ripple processing.

* Optional synchronous rectification technology, higher efficiency and lower temperature rise.

* Output short-circuit, over-current, over-power protection functions are perfect.


Product Detail

Product Tags

Electrical Parameters/Specifications:

Model No  TA18-5V3A TA12-12V1.5A TA18-12V2A TA18-24V1A
Output      DC voltage                              5V 12V 12V 24V
Rated current                            3A 1.5A 2A 1A
Current range                         0-3A 0-1.5A 0-2A 0-1A
rated power                           15W 18W 24W 24W
Ripple and Noise (Maximum) 50mVp-p 80mVp-p 80mVp-p 100mVp-p
Voltage accuracy ±5% ±3% ±3% ±3%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±1% ±1% ±1%
Efficiency (TYP) 78% 85% 85% 88%
Voltage adjustment range not adjustable
Start-up, rise time                  1500ms,30ms/220VAC  2500ms,30ms/110VAC(full load)
Input         voltage range                        VAC90-264V  VDC127~370V (Please refer to "Derating Curve")
Frequency Range                  47~63Hz
AC current (TYP) 0.3A/220VAC ,0.5A/110VAC
Inrush current (TYP) COLD START 35A
leakage current                          <2mA/240VAC
Current
Protection     
short circuit Protection mode: hiccup mode, automatic recovery after abnormal condition is removed
over current 110%~200% of rated output current
over power 110%~200% of rated output power
Environmental Operating temperature ﹣20~﹢60℃ (Please refer to "Derating Curve")
Working humidity                    20~90%RH, no condensation
Storage temperature and humidity                   ﹣40~﹢85℃,10~95%RH
Vibration resistant                      10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes
Safety and Electromagnetic Compatibility        safety regulations Refer to CE, IT general standard design
Pressure resistance I/P-O/P:1.5KVAC
Insulation resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH
Mechanical Size (L*W*H) 65*32.5*16mm(L*W*H)
weight About0.3Kg/PCS

 

Remarks:

Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.

Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. 

Load regulation measurement method: From 0% to 100% rated load.

The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.

Derating Curve

Static Characteristic Curve

Picture-22
Picture-11

*Mechanical Dimension Drawing: unit MM

*Power Circuit Diagram:


  • Previous:
  • Next:

  • Write your message here and send it to us