Factory 5V 4A 20W PSE Certificated DC Power adapter
SPECIFICATION FOR APPROVAL
Switching power Supply
Product Name: Input:100~240VAC 50/60Hz Output:DC5.0V4.0A
Model No:BSG025W-JP0504000H
1、 DESCRIPTION:
This specification is suitable for BSG025W-JP0504000H type switching power supply.
The purpose of the document is to specify the functional requirements of a 20.0W switching power supply.
2、INPUT CHARACTERISTICS:
2.1 Input Voltage:
Rated Voltage:100-240Vac
Variation Range:90-264Vac
2.2 INPUT FREQUENCY:
Rated Frequency: 50/60Hz.
Variation Frequency:47-63Hz
2.3 INPUT CURRENT:
0.6Amps max At any input voltage and rated, DC output rated load.
2.4 INRUSH CURRENT:
30 Amps Max. Cold start at 240Vac input, with rated load and 25℃ ambient.
2.5 AC LEAKAGE CURRENT
0.25mA Max. at 240Vac input.
3、OUTPUT CHARACTERISTICS:
3.1 Power output
Voltage |
Min. Load |
Rated. Load |
Peak |
Output power |
5.0Vdc |
0.00A |
4.0A |
20W |
24W |
3.2 Combined Load/Line Regulation
Voltage |
Min. Load |
Rated. Load |
Load Regulation |
Voitage range |
5.0Vdc |
0.00A |
4.0A |
±5% |
4.4V-5.6V |
3.3 Ripple and Noise:
Under nominal voltage and nominal load,the ripple and noise are as follows when measure with Max.Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.
Voltage Ripple and Noise(Max.)
+5.0Vdc 120mV p-p
3.4 Turn on delay time:
3Second Max.at 115Vac input and output Max.load.
3.5 Rise time:
40 mS Max.at 115Vac input and output Max load.
3.6 Hold up time:
5 mS Min.at 115Vac input and output Max.Load.
3.7 Average Effiviency
Average Effiviency 75%Min., at 115/230Vac input and output 100%Load、75%Load、50%Load、 25%Load Adapter meet effcicncy Level V
3.8 Standby Power Loss
Input 115/230Vac ,The No-Load power≤ 0.3 W
4、PROTECTION FUNCTION:
4.1 Short circuit test:
The power supply will be auto recovered when short circuit faults remove.
4.2 Over current Protection:
The power supply will be auto recovered when over current faults remove.
Over Current Point Limited: Iocp≤4.8A (100-240Vac)
4.3 Over Voltage Protection:
The power supply will auto recovered when faults remove 120%~170%.
5、ENVIRONMENTAL REQUIREMET:
5.1 Operating Temperature:
0℃ to 40℃,Full load, Normal operation.
5.2 Storage Temperature:-20℃ to 80℃
With Outer shell
5.3 Relative Humidity:
5%(0℃)-90%(40℃)RH,72Hrs,Full load, Normal operating.
5.4 Vibration:
1. Test Standard: International Electrotechnical and Electronic Commission
Operating: IEC 721-3-3 3M3
5~9Hz,A=1.5mm
(9~200Hz,Acceleration 5m/S2)
2. Transportation:
IEC 721-3-2 2M2
5-9Hz,A=3.5mm
9~200Hz,Acceleration=5m/S2
200~500Hz,Acceleration=15m/S2
3. Axes,10 cycles per axis.
No permanent damage may occur during testing.
The SAMPLE has to restore to its original situation after power off/on..
5.5 Dropping Packed:
1M for wallmount type and 760mm for desktop type as above described.
The horizontal surface consists of hardwood at least 13mm thick, mounted on two layers of plywood each 19mm to 20mm thick,all supported on a concrete or equivalent non-resilient floor.
6、SAFETY REQUIREMENT:
6.1 Safety: accord with UL/CUL-(UL62368-1), CCC-(GB4943.1), JP(J60950-1),CE/GS(EN61558-2-16) etc。
6.2 DIELECTRIC STRENGTH Hi-Pot:
Primary to secondary:3000Vac 5mA/3S for type test.
6.3 Iusulation resistance:
Primary to secondary:10MΩ min at 500V DC.
6.4 EMI STANDARD
Meets the Limits of
<1>.Fcc part15 class B rules
<2>.EN55032 class B rules 2015;EN55035 2017
<3>.GB9254-1998,GB17625.1-2003
<4>.J55032