Products

Black color 12V 5A Output 60W AC DC adapter

Specifications for this item

Item Code: KY-A008

Product Name: AC/DC Adapter

Model: QL065-1205000D3

Input:100~240V 50/60Hz 1.5A

Output: 12V 5A (60W)

Wire Specification: UL2468 18AWG DC Cable

Cable Length: L=1.5m

DC Connector: 5.5*2.1

Certificate: SAA,ETL,CCC,CE,FCC,PSE


Product Detail

Product Tags

SPECIFICATION FOR APPROVAL

Product Name: Switching power Supply

Model No:AS065-1205000D3

1、SCOPE:

This specification applies to AS065-1205000D3

The purpose of the document is to specify the functional requirements of at  60 W switching power supply.

2、INPUT CHARACTERISTICS:

2.1 Input Voltage:

Rated Voltage:100-240Vac

Variation Range:90-264Vac

2.2  INPUT FREQUENCY:

Rated Frequency: 50/60Hz.

Variation Frequency:47-63Hz

2.3 INPUT CURRENT:

1.2Amps max At any input voltage and rated, DC output rated load.

2.4  INRUSH CURRENT:

50 Amps Max. Cold start at 240Vac input, with rated load and 25℃ ambient.

2.5  AC LEAKAGE CURRENT

0.25mA Max. at 240Vac input.

3、OUTPUT CHARACTERISTICS:

3.1 Power output

Voltage

Min. Load

Rated. Load

Peak

Output power

12Vdc

0.01A

5A

 

60W

3.2  Combined Load/Line Regulation

Voltage

Min. Load

Rated. Load

 Output Voltage Range

Load Regulation

12Vdc

0.01A

5A

11.4V-12.6Vdc

±5%

3.3  Ripple and Noise:

Under nominal voltage and nominal load,the ripple and noise are as follows when measure with Max.Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.                  

Voltage                Ripple and Noise(Max.)

+12Vdc                  200Mv p-p

3.4 Turn on delay time:

When the input 115Vac is turned on and the output maximum load is turned on, the maximum start delay time of the output voltage is 3S..

3.5 Rise time:

When input 115Vac and output maximum load are applied, the maximum rise time of output voltage from zero volt to rated output voltage is 40 mS.

3.6 Hold up time:

When input 115 Vac and output maximum load, turn off input voltage, output voltage

 minimum hold time is 5 Ms.

3.7  NO-load Power:

NO-load Power0.1W,At 115/230Vac input voltage.

3.8  Overshoot:

15% Max.When power supply at turn or turn off.

4、PROTECTION FUNCTION:

4.1 Short circuit test:

The power supply will be auto recovered when short circuit faults remove.

4.2 Over current Protection:

The power supply will be auto recovered when over current faults remove.

(2)Output current 5.1-12A will be protected

5、ENVIRONMENTAL REQUIREMET:

5.1  Operating Temperature:

0℃ to 40℃,Full load, Normal operation.

5.2  Storage Temperature:-10℃ to 80

With package

5.3  Relative Humidity:

5%(0℃)~90%(40℃)RH,72Hrs,Full load, Normal operating.

5.4  Vibration:

1. Test Standard: International Electrotechnical and Electronic Commission

Operating: IEC 721-3-3 3M3

5~9Hz,A=1.5mm

Acceleration(9~200Hz, Acceleration 5m / S2)

2. Transportation:

IEC 721-3-2 2M2

5-9Hz,A=3.5mm

9~200Hz, Acceleration=5m / S2

200~500Hz, Acceleration=15m / S2

3. Axes,10 cycles per axis.

No permanent damage may occur during testing.

The SAMPLE has to restore to its original situation after power off/on..

6、SAFETY AND EMI REQUIREMENT:

6.1  High Voltage/DIELECTRIC STRENGTH Hi-Pot:

Primary side to secondary side: AC3000V, maximum 5mA max, Standard Test for 1 minute.

Production test 3000V 5mA 3 seconds.

7、 MECHANICAL REQUIREMENT:

7.1  Enclosure:

Desktop black shell 114*54*34MM  C13 word tail

xdfd (2)

Tolerance ±5 in mm

8、LABEL:

xdfd (3)

9、OUTLINE DIMENSION:

Wire gauge:    2468  18#    Total  Length   1.5   m,DC Connector dimension is     5.5*2.1*10mm   
Out Cord:  2468   18#   Length:   1.5  M, DC plug    5.5*2.1*10mm    

xdfd (1)

  • Previous:
  • Next:

  • Write your message here and send it to us