Black color 12V 5A Output 60W AC DC adapter
SPECIFICATION FOR APPROVAL
Product Name: Switching power Supply
Model No:AS065-1205000D3
1、SCOPE:
This specification applies to AS065-1205000D3
The purpose of the document is to specify the functional requirements of at 60 W switching power supply.
2、INPUT CHARACTERISTICS:
2.1 Input Voltage:
Rated Voltage:100-240Vac
Variation Range:90-264Vac
2.2 INPUT FREQUENCY:
Rated Frequency: 50/60Hz.
Variation Frequency:47-63Hz
2.3 INPUT CURRENT:
1.2Amps max At any input voltage and rated, DC output rated load.
2.4 INRUSH CURRENT:
50 Amps Max. Cold start at 240Vac input, with rated load and 25℃ ambient.
2.5 AC LEAKAGE CURRENT
0.25mA Max. at 240Vac input.
3、OUTPUT CHARACTERISTICS:
3.1 Power output
Voltage |
Min. Load |
Rated. Load |
Peak |
Output power |
12Vdc |
0.01A |
5A |
|
60W |
3.2 Combined Load/Line Regulation
Voltage |
Min. Load |
Rated. Load |
Output Voltage Range |
Load Regulation |
12Vdc |
0.01A |
5A |
11.4V-12.6Vdc |
±5% |
3.3 Ripple and Noise:
Under nominal voltage and nominal load,the ripple and noise are as follows when measure with Max.Bandwidth of 20MHz and Parallel 47uF/0.1uF,crossed connected at testing point.
Voltage Ripple and Noise(Max.)
+12Vdc 200Mv p-p
3.4 Turn on delay time:
When the input 115Vac is turned on and the output maximum load is turned on, the maximum start delay time of the output voltage is 3S..
3.5 Rise time:
When input 115Vac and output maximum load are applied, the maximum rise time of output voltage from zero volt to rated output voltage is 40 mS.
3.6 Hold up time:
When input 115 Vac and output maximum load, turn off input voltage, output voltage
minimum hold time is 5 Ms.
3.7 NO-load Power:
NO-load Power≤0.1W,At 115/230Vac input voltage.
3.8 Overshoot:
15% Max.When power supply at turn or turn off.
4、PROTECTION FUNCTION:
4.1 Short circuit test:
The power supply will be auto recovered when short circuit faults remove.
4.2 Over current Protection:
The power supply will be auto recovered when over current faults remove.
(2)Output current 5.1-12A will be protected
5、ENVIRONMENTAL REQUIREMET:
5.1 Operating Temperature:
0℃ to 40℃,Full load, Normal operation.
5.2 Storage Temperature:-10℃ to 80℃
With package
5.3 Relative Humidity:
5%(0℃)~90%(40℃)RH,72Hrs,Full load, Normal operating.
5.4 Vibration:
1. Test Standard: International Electrotechnical and Electronic Commission
Operating: IEC 721-3-3 3M3
5~9Hz,A=1.5mm
Acceleration(9~200Hz, Acceleration 5m / S2)
2. Transportation:
IEC 721-3-2 2M2
5-9Hz,A=3.5mm
9~200Hz, Acceleration=5m / S2
200~500Hz, Acceleration=15m / S2
3. Axes,10 cycles per axis.
No permanent damage may occur during testing.
The SAMPLE has to restore to its original situation after power off/on..
6、SAFETY AND EMI REQUIREMENT:
6.1 High Voltage/DIELECTRIC STRENGTH Hi-Pot:
Primary side to secondary side: AC3000V, maximum 5mA max, Standard Test for 1 minute.
Production test 3000V 5mA 3 seconds.
9、OUTLINE DIMENSION:
Wire gauge: 2468 18# Total Length 1.5 m,DC Connector dimension is 5.5*2.1*10mm
Out Cord: 2468 18# Length: 1.5 M, DC plug 5.5*2.1*10mm