Products

50W 60W 72W open frame switching power supply Factory

Specifications for this item

* Ultra small shape design, easy to install.

* Full load operation, low temperature rise

* Refer to safety requirements, isolation withstand voltage is greater than 1500VAC.

* Refer to EMC design, can be certified, low ripple processing.

* Optional synchronous rectification technology, higher efficiency and lower temperature rise.

* Output short-circuit, over-current, over-power protection functions are perfect.


Product Detail

Product Tags

Electrical Parameters/Specifications:

    Model No TA65-5V10A TA65-12V5A TA65-24V3A TA65-36V2A
 Output      DC voltage                                5V 12V 24V 36V
Rated current                            10A 5A 3A 2A
Current range                        0-10A 0-5A 0-3A 0-2A
rated power                         50W 60W 72W 72W
Ripple and Noise (Maximum) 50mVp-p 100mVp-p 120mVp-p 150mVp-p
Voltage accuracy ±5% ±3% ±3% ±3%
Linear adjustment rate ±0.5% ±0.5% ±0.5% ±0.5%
Load Regulation ±1% ±1% ±1% ±1%
Efficiency (TYP) 88% 85% 88% 89%
Voltage adjustment range not adjustable
Start-up, rise time              1500ms,30ms/220VAC  2500ms,30ms/110VAC(full load)
Input         voltage range                       VAC100-240V(85-264V)  VDC127~370V (Please refer to "Derating Curve")
Frequency Range                   50/60Hz
AC current (TYP) 0.6A/220VAC,1.2A/100V 0.65A/220VAC,1.25A/100V
Inrush current (TYP) COLD START 45A
leakage current                           <2mA/240VAC
Current
Protection   
short circuit Protection mode: hiccup mode, automatic recovery after abnormal condition is removed
over current 110%~200% of rated output current
over power 110%~200% of rated output power
Environmental Operating temperature ﹣20~﹢60℃ (Please refer to "Derating Curve")
Working humidity                    20~90%RH, no condensation
Storage temperature and humidity                      ﹣40~﹢85℃,10~95%RH
Vibration resistant                        10~500Hz, 2G 10 minutes/cycle, X, Y, Z axis each 60 minutes
Safety and Electromagnetic Compatibility        safety regulations Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements
Pressure resistance I/P-O/P:3KVAC
Insulation resistance I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/70%RH
Electromagnetic Compatibility Emissions Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements
Electromagnetic Compatibility Immunity Refer to CE, CCC, IT general standard design, actually need your company to pass the test according to the certification requirements
Mechanical Size (L*W*H) 130*50*30mm(L*W*H)
weight About0.5Kg/PCS

 

Remarks:

Unless otherwise specified, all specifications are measured under the input of 220VAC, rated load, and 25°C ambient temperature.

Ripple and noise measurement method: use a 30CM twisted pair cable, and the terminals should be connected in parallel with 0.1uf and 47uf capacitors, and measure at 20MHZ bandwidth.

Accuracy: including setting error, linear adjustment rate and load adjustment rate.

Linear adjustment rate measurement method: under rated load, from low voltage to high voltage test. 

Load regulation measurement method: From 0% to 100% rated load.

The power supply should be regarded as a part of the components in the system, and the relevant confirmation of electromagnetic compatibility should be carried out in conjunction with the terminal equipment.

Derating Curve

Static Characteristic Curve

Remarks
Remarks

*Mechanical Dimension Drawing: unit MM